62639-0
PhenX - respiratory - spirometry protocol 091601
Trial
Status Information
- Status
- TRIAL
Term Description
A spirometric test requires that the subject take a full, deep breath and then exhale as forcefully as possible into a hand-held portable spirometer. The subject's effort is called the forced expiratory maneuver and most commonly measures the amount and speed of air that is exhaled. The total amount (volume) of air exhaled is called the forced vital capacity (FVC). The amount (volume) of air exhaled in 1 second is called the forced expiratory volume in 1 second (FEV1). While hand-held spirometers are commonly used in clinical research studies, the same results can be obtained from more sophisticated floor-mounted devices that are typically available in a respiratory function testing laboratory. Numerous instructions are embedded in the protocol and in Table 1 of the protocol.
Reference Information
Type | Source | Reference |
---|---|---|
Citation | Consensus measures for Phenotypes and Exposures | European Respiratory Journal, 26(2), 319-338. |
Panel Hierarchy
Details for each LOINC in Panel LHC-Forms
LOINC | Name | R/O/C | Cardinality | Example UCUM Units |
---|---|---|---|---|
62639-0 | PhenX - respiratory - spirometry protocol 091601 | |||
Indent64591-1 | Data type | |||
Indent20053-5 | Atmospheric pressure | mm[Hg] | ||
Indent60832-3 | Room temperature | Cel;[degF] | ||
Indent65643-9 | Relative humidity (%) | % | ||
Indent64592-9 | FVC quality attribute | |||
Indent64593-7 | FEV1 quality attribute | |||
Indent64594-5 | Effort attribute | |||
Indent64595-2 | Deleted maneuver | |||
Indent64596-0 | Acceptable maneuver | |||
Indent64597-8 | Technician quality control code | |||
Indent64598-6 | Computer quality code | |||
Indent64599-4 | Plateau achieved | |||
Indent64600-0 | Review | |||
Indent65644-7 | BTPS factor | {ratio} | ||
Indent64601-8 | Date of review | |||
Indent65645-4 | Reviewer initials | |||
Indent65646-2 | Manufacturer name | |||
Indent41927-5 | Oxygen saturation device Vendor model code | |||
Indent41928-3 | Oxygen saturation device Vendor serial number | |||
Indent41925-9 | Type of Oxygen saturation device | |||
Indent65652-0 | Testing facility name | |||
Indent65647-0 | City | |||
Indent52830-7 | State, district or territory federal abbreviation Facility | |||
Indent45401-7 | Postal code [Location] | |||
Indent65649-6 | Country | |||
Indent65650-4 | ||||
Indent65651-2 | Phone number | |||
Indent64991-3 | Date of observation | |||
Indent64603-4 | Calibration result | |||
Indent64991-3 | Date of observation | |||
Indent64604-2 | Technician ID | |||
Indent64605-9 | Maneuver number | |||
Indent30525-0 | Age | a | ||
Indent3137-7 | Body height Measured | [in_us];cm;m | ||
Indent3141-9 | Body weight Measured | [lb_av];kg | ||
Indent46098-0 | Sex | |||
Indent64606-7 | Race, 2-character race code | |||
Indent21112-8 | Birth date | {mm/dd/yyyy} | ||
Indent64607-5 | Reference values source | |||
Indent65817-9 | Reference values correction factor | |||
Indent64608-3 | Testing position | |||
Indent65653-8 | Test type | |||
Indent65818-7 | Medication [Mass/volume] Dose | |||
Indent65866-6 | Methacholine [Mass] of Dose | mg | ||
Indent19868-9 | Forced vital capacity [Volume] Respiratory system by Spirometry | L | ||
Indent65654-6 | Extrapolated volume | mL | ||
Indent20150-9 | FEV1 (liters) | L | ||
Indent65655-3 | FEV6 | L | ||
Indent33452-4 | Maximum expiratory gas flow Respiratory system airway | L/min | ||
Indent19945-5 | Gas flow FEV 25%-75% airway | L/s | ||
Indent19866-3 | Vital capacity [Volume] Respiratory system by Spirometry | L | ||
Indent65819-5 | Forced expiratory time | s | ||
Indent65820-3 | Time to PEF | |||
Indent19869-7 | Forced vital capacity [Volume] Respiratory system Predicted | L | ||
Indent20149-1 | FEV1 Predicted | L | ||
Indent65656-1 | Predicted FEV6 | L | ||
Indent19925-7 | FEV1/FVC Predicted | % | ||
Indent65658-7 | Predicted FEV1/FEV6% | % | ||
Indent8251-1 | Service comment | |||
Indent65660-3 | Original sampling interval | |||
Indent65821-1 | FEF25% | L/s | ||
Indent65822-9 | FEF50% | L/s | ||
Indent65823-7 | FEF75% | L/s | ||
Indent65824-5 | FEF90% | L/s | ||
Indent65661-1 | Number of data points | {#} | ||
Indent65662-9 | Flow data points (mL/s; variable number contained in number of data points) |
Fully-Specified Name
- Component
- PhenX - respiratory - spirometry protocol 091601
- Property
- -
- Time
- Pt
- System
- ^Patient
- Scale
- -
- Method
- PhenX
Additional Names
- Long Common Name
- PhenX - respiratory - spirometry protocol 091601
- Short Name
- Resp spirometry proto
Survey Question
- Source
- PX091601
Basic Attributes
- Class
- PANEL.PHENX
- Type
- Clinical
- First Released
- Version 2.36
- Last Updated
- Version 2.66 (NAM)
- Change Reason
- Updated the PhenX ID from "PhenX.<ID>" to "PX<ID>" in Survey Question Source field to align with the variable identifier used in the PhenX Toolkit.; Added the PhenX protocol ID to the Component to clearly define the protocol version for which this panel is based upon.
- Panel Type
- Panel
Member of these Panels
LOINC | Long Common Name |
---|---|
62611-9 | PhenX domain - Respiratory |
Language Variants Get Info
Tag | Language | Translation |
---|---|---|
el-GR | Greek (Greece) | PhenX - αναπνευστικό - σπιρομέτρηση πρωτόκολλο 091601: Synonyms: PhenX - αναπνευστικό - σπιρομέτρηση πρωτόκολλο 091601 |
es-MX | Spanish (Mexico) | PhenX - respiratorio - protocolo de espirometría 091601: |
it-IT | Italian (Italy) | PhenX - respiratorio - spirometria, protocollo: Synonyms: Panel PhenX paziente PhenX Punto nel tempo (episodio) |
ru-RU | Russian (Russian Federation) | PhenX - дыхание - спирометрия протокол: Synonyms: Точка во времени; |
zh-CN | Chinese (China) | PhenX - 呼吸系统 - 肺活量测定方案 091601: Synonyms: Consensus measures for Phenotypes and eXposures; |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
- CodeSystem lookup
- https:
//fhir.loinc.org/CodeSystem/$lookup?system=http: //loinc.org&code=62639-0 - Questionnaire definition
- https:
//fhir.loinc.org/Questionnaire/?url=http: //loinc.org/q/62639-0
LOINC Copyright
Copyright © 2025 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://