62709-1
PhenX - retinal digital photography protocol 111501
Trial
Status Information
- Status
- TRIAL
Term Description
Two 45 digital retinal images (Field 1 and 2) will be taken of each eye of the participant using the Canon Non-Mydriatic Retinal CR6-45NM camera with a digital Canon D60 camera back (6.3 megapixels per image). Field 1 is centered on the optic disc and Field 2 is centered on the macula, providing photographic documentation of the optic disc, macula, and substantial portions of the temporal arcades. These photographs may be graded for retinal microvascular characteristics, including focal arteriolar narrowing, arterio-venous nicking, retinopathy (e.g., microaneurysms, retinal hemorrhages) and other conditions. In addition, generalized arteriolar narrowing is quantified using a computer assisted measure of retinal vascular caliber. Training to take consistent gradable images is required although training is not extensive and quality of photography should be monitored throughout the entire study. Systematic grading of the images with adequate quality control procedures is imperative to minimize grader variability and to minimize misclassification leading to spurious or erroneous null findings. This protocol uses the Canon Non-Mydriatic Retinal CR6-45NM camera with a digital Canon D60 camera back (6.3 megapixels per image). Other ophthalmic imaging cameras can be used. If other instruments are used, the reproducibility of the measurements should be comparable to those acquired with this protocol. The Ocular Working Group recommends cameras that capture images that are 5 mega-pixels or larger for use in grading and vessel measurement protocols. When other instruments are used to capture digital retinal images, the manufacturer and model of equipment should be recorded. These other cameras may require some different steps than are described in this protocol. Investigators should follow the equipment manufacturer's instructions to ensure quality control. In addition, this protocol uses EyeQSL,software which is commercially available through Digital Healthcare Inc. The Ocular Working Group notes that other ophthalmic imaging packages are available through other vendors that are similar in nature. These other software packages may require some different steps than are described in this protocol. Investigators should follow the manufacture's instructions to ensure quality control. Please be sure to record the manufacturer and model and version of the software used.
Reference Information
Type | Source | Reference |
---|---|---|
Image | Consensus measures for Phenotypes and Exposures | Diagram of the location of two eye fields
![]() |
Panel Hierarchy
Details for each LOINC in Panel LHC-Forms
LOINC | Name | R/O/C | Cardinality | Example UCUM Units |
---|---|---|---|---|
62709-1 | PhenX - retinal digital photography protocol 111501 | |||
Indent46496-6 | Agency patient number during assessment period [CMS Assessment] | |||
Indent65884-9 | Photographer ID | |||
Indent65883-1 | Retinal digital photography instrument model | |||
Indent65898-9 | Right Eye Fields photographed in the Retinal Digital Photography | |||
Indent65899-7 | Other eye field Right eye [Retinal digital photography] | |||
Indent65900-3 | Right Eye Flash Setting in the Retinal Digital Photography | |||
Indent65901-1 | Right Eye Number of images captured in the Retinal Digital Photography | {#} | ||
Indent65902-9 | Right Eye Estimated Diameter of Pupil at 1st Photograph | mm | ||
Indent65903-7 | Right Eye Describe any problems or unusual findings | |||
Indent65904-5 | Left Eye Flash Setting in the Retinal Digital Photography | |||
Indent65905-2 | Left Eye Number of images captured in the Retinal Digital Photography | |||
Indent65900-3 | Right Eye Flash Setting in the Retinal Digital Photography | |||
Indent65901-1 | Right Eye Number of images captured in the Retinal Digital Photography | {#} | ||
Indent65906-0 | Left Eye Estimated Diameter of Pupil at 1st Photograph | mm | ||
Indent65907-8 | Left Eye Describe any problems or unusual findings |
Fully-Specified Name
- Component
- PhenX - retinal digital photography protocol 111501
- Property
- -
- Time
- Pt
- System
- ^Patient
- Scale
- -
- Method
- PhenX
Additional Names
- Long Common Name
- PhenX - retinal digital photography protocol 111501
- Short Name
- Retinal digital photography proto
Survey Question
- Source
- PX111501
Basic Attributes
- Class
- PANEL.PHENX
- Type
- Clinical
- First Released
- Version 2.36
- Last Updated
- Version 2.66 (NAM)
- Change Reason
- Updated the PhenX ID from "PhenX.<ID>" to "PX<ID>" in Survey Question Source field to align with the variable identifier used in the PhenX Toolkit.; Added the PhenX protocol ID to the Component to clearly define the protocol version for which this panel is based upon.
- Panel Type
- Panel
Member of these Panels
LOINC | Long Common Name |
---|---|
62677-0 | PhenX domain - Ocular |
Language Variants Get Info
Tag | Language | Translation |
---|---|---|
el-GR | Greek (Greece) | PhenX - ψηφιακή φωτογράφιση αμφιβληστροειδούς πρωτόκολλο 111501: Synonyms: PhenX - ψηφιακή φωτογράφιση αμφιβληστροειδούς πρωτόκολλο 111501 Αμφιβληστροειδής |
es-MX | Spanish (Mexico) | PhenX - protocolo de fotografía digital de retina 111501: |
it-IT | Italian (Italy) | PhenX - fotografia digitale della retina, protocollo: Synonyms: Panel PhenX paziente PhenX Punto nel tempo (episodio) |
ru-RU | Russian (Russian Federation) | PhenX - ретинальной цифровой фотографии протокол: Synonyms: PhenX - сетчаточной цифровой фотографии протокол Точка во времени; |
zh-CN | Chinese (China) | PhenX - 视网膜数字摄影术方案 111501: Synonyms: Consensus measures for Phenotypes and eXposures; |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
- CodeSystem lookup
- https:
//fhir.loinc.org/CodeSystem/$lookup?system=http: //loinc.org&code=62709-1 - Questionnaire definition
- https:
//fhir.loinc.org/Questionnaire/?url=http: //loinc.org/q/62709-1
LOINC Copyright
Copyright © 2025 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://